Please click ' start' miner

27/05/2011

SONY TELEVISION BLINKING CODES


Many of the later model Sony TV’s have a built in self-diagnosis function. If the timer/standby indicator is blinking, this could be an indication of a problem with the unit. The diagnostic blinking will occur automatically with no action required by you to engage it.

The timing of the blinking you see would be as follows: two to nine blinks, (depending on the fault), about a third of a second apart, then a pause for 3 seconds, then the two to nine blinks about a third of a second apart again.

Here is a list of the problems that might have occurred indicated by the number of blinks. The words in parentheses are those, which you will see for each of these faults on a diagnosis screen described later in this article.

* Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open).
* Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective.
* One blink - not used for the self-diagnosis
* Two blinks - B+ over current protection (OCP), unit goes to the standby mode then displays the 2 blink fault. Could be a short in the power supply of any of the circuits.
* Three blinks - B+ over voltage protection (OVP), unit goes to the standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672.
* Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505
* Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly.
* Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206.
* Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits.

* Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (flyback transformer), or the associative components in the high voltage circuits are defective on the D board.


* Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. Or Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negitive).

* Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the " D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

Intermittent problems? This is a great feature. You can also bring up these fault codes on-screen to see a list of the problem numbers with the abbreviation of the problem and the number of times this problem has occurred. This is slightly different than entering the service mode. To see the diagnostic screen, press the following buttons: Display, Channel, 5, volume Minus, ( not plus ) then Power. This brings up a screen with a list of the problems and number of times they have occurred. Each of the problems named, are abbreviated as, "OCP", "OVP", "V STOP", ETC. We have repeated them in parentheses in the text for the "Blinks" described above so you can correlate between the diagnostic screen and the blink codes.

Now that you know about these self-diagnostics, how do you use them? Say that you have a set with a black screen. You see that the LED is blinking four times. This would tell you that you have no vertical sweep, which is why the video is muted. If it was blinking 6 times, you would know that you have a horizontal fault. It's not a sure cure..

IMPORTANT: After you repair the unit, you MUST clear the values on this diagnostic screen. These codes do not reset themselves after the fault is corrected, so if you don't clear them, you'll be seeing "old" fault codes the next time you enter this screen. Clearing is done by going into the service mode (display, channel, 5, volume plus, then power ). Press 8 and Enter, which returns everything to the factory preset condition.

This post is directed towards helping folks with the diagnosis of problems with their Sony Television set. The genesis of this post is based questions I have received from my post on fixing the retrace lines on you Sony HDTV Projection and some additional help from a Sony TV Repair & Service Manual for my KP-51HW40 Projection HD Television set.

If you are having some problems with your Sony Television, then this post is for you. Generally speaking, when there is trouble with your Sony Television set -- it indicates the issue in either the diagnostic mode, or even more commonly by flashing a series of LED blinks or flashes on the front of your television. Each set or frequency of the blinks indicates a very specific problem with the television itself. In some cases, you may be able to repair the television set yourself -- or in the worst case you may need to order parts, call a local repair shop to the have a repairman sent out, or even purchase a new television set.

First off, here are the list of codes and what they generally mean on my set (which applies to many recent model Sony Television sets. Sony has provided a "self-diagnosis function" with your TV, that in the case of abnormalities or problems the LED or red blinking light on the Timer/Standby indicator flashes a number of times to indicate the issue. Here are the values of the various blinks.

* 0 times, Diagnosis: Power does not turn on. Possible causes include: Power cord is not plugged in, Fuse is burned out (F6001) (G board). Symptoms of the problem: Power does not come on, No power is supplied to the unit, AC power supply is faulty.
* 2 times, Diagnosis: B overcurrent (OCP). Possible causes: H. OUT (Q8024) is shorted. (D board), +B PWM (Q8035, 8038) is shorted. (D board) Symptoms of the problem: Power does not come on, Load on power line is shorted.
* 3 times, Diagnosis: +B overvoltage (OVP). Possible causes: IC501 is faulty (G board), IC5002 is faulty (G board). Symptoms of the problem: TV has entered standby mode.
* 4 times, Diagnosis: Vertical deflection stopped. Possible causes: +- 15V is not supplied. (D board), IC8003 is faulty. (A board) Symptoms of the problem: TV has entered standby state after horizontal raster, Vertical deflection pulse is stopped, Power line is shorted or power supply is stopped.
* 5 times, Diagnosis: White balance failure (Not balanced) Possible causes: Video out (IC7101, 7201, 7301) is faulty (CR, CG, CB board), CRT drive (IC309) is faulty (A board), G2 is improperly adjusted. Symptoms of the problem: No raster is generated, CRT cathode current detection reference pulse output is small.
* 6 times, Diagnosis: LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture.
* 7 times, Diagnosis: Horizontal deflection stopped. Possible cause: Q8035, 8038 is shorted. (D board)
* 8 times, Diagnosis: High voltage error. Possible cause: T8005 is faulty. (D board)
* 9 times, Diagnosis: Audio error. Possible causes: +- 19V line is shorted. (A, B boards), IC708 is faulty. (A board), PS701 or PS702 is opened. (A board). Symptoms of the problem: No sound

Hopefully, the descriptions of the blinking lights and the symptoms and problems will point you in the right direction to tell the problem with you Sony Projection Screen Television. If it is not enough, do not worry -- in the coming few posts I will talk about entering the Diagnosis and Service modes for your television set!

15 comments:

  1. Helpful information thanks.
    "* 2 times, Diagnosis: B overcurrent (OCP). Possible causes: H. OUT (Q8024) is shorted. (D board), +B PWM (Q8035, 8038) is shorted. (D board) Symptoms of the problem: Power does not come on, Load on power line is shorted."
    Can you tell me what is the reference of "D Board"
    on KDL-52xbr4.

    Best Regards

    Frank

    ReplyDelete
  2. 3 blinks on a kv36hs510 where is the B board in the tv and where are ic5002 and ic501? R they the chips ?

    ReplyDelete
  3. Hi, Im lady and will try and repair Sony TV,.
    if you can advise me pleease. in steps.
    You sound clear and easy to follow
    It blinks 9x intermittently.
    The model no is KDL-37s3100
    thankyou and regards Irene

    ReplyDelete
  4. http://tampatec.blogspot.in/2015/03/sony-bravia-kdl-lcd-tv-error-codes-for.html

    ReplyDelete
  5. Sony crt tv just turn on 2sec after standby... no blinking... pls help

    ReplyDelete
  6. Please help sony kv21m83 4 time red led blink

    ReplyDelete
  7. My Sony 14inch crt tv bm14m40 blinking 4times after 1hours of started tv please send me what is problem running ok for 1hours after standby and blinking 4times

    ReplyDelete
  8. My TV 29inch eight blink led please help me

    ReplyDelete
  9. i have problem with tv sony crt kv-xf25m80..no display but the avl resistor are all good..maybe you have some help with this problem to me sir..thankyou very much sir..

    ReplyDelete
  10. i have problem with tv sony crt kv-xf25m80..no display but the avl resistor are all good..maybe you have some help with this problem to me sir..thankyou very much sir..

    ReplyDelete
  11. Sony cry modelno kv-ar14p52 probleis tv on display ok but sum after tv is standby with 4 time blinking how can solv

    ReplyDelete
  12. Sony red led two time blinking

    ReplyDelete